How to Improve the Prediction of Quadrupled Semitendinosus and Gracilis Autograft Sizes With Magnetic Resonance Imaging and Ultrasonography


Por: Erquicia, JI, Gelber, PE, Doreste, JL, Pelfort, X, Abat, F, Monllau, JC

Publicada: 1 ago 2013
Resumen:
Background: Hamstring tendon grafts may have an unacceptable size for use in anterior cruciate ligament (ACL) reconstruction. Magnetic resonance imaging (MRI) has been proposed to predict the diameters of hamstring tendon grafts. Hypothesis: Preoperative ultrasonography (US) might reliably anticipate intraoperative 4-strand semitendinosus and gracilis tendon (4ST-GT) graft sizes similarly to MRI. An MRI evaluation of the hamstring tendons with a higher magnification may improve the accuracy of the method. Study Design: Cohort study (diagnosis); Level of evidence, 2. Methods: A total of 33 patients undergoing ACL reconstruction with a 4ST-GT graft and MRI performed at our institution were included. The cross-sectional area (CSA) of each semitendinosus tendon (ST) and gracilis tendon (GT) was calculated preoperatively with US and with MRI under 2x and 4x magnification. Intraoperative measurement of the final diameter of the 4ST-GT using a closed-hole sizing block with 0.5-mm increments was made. Pearson correlation coefficients were calculated to determine the relationship between the final intraoperative graft diameter of the 4ST-GT and the CSA of the ST and GT measured with US and MRI with 2x and 4x magnification. Simple linear regression was also calculated to attempt to predict the graft diameter based on given measurements. Results: There were statistically significant correlations between the measured CSA with US and both MRI magnifications with the 4ST-GT diameter. However, MRI under 4x magnification showed a much higer correlation (0.86) than MRI under 2x magnification (0.54) or US (0.51). Final graft diameters 8 mm were observed in 80.8% of patients with a CSA >14 mm(2), in 76.9% of patients with a CSA >25 mm(2), and in 96.2% of patients with a CSA >17 mm(2) measured with US, 2x magnification of MRI, and 4x magnification of MRI, respectively. Conclusion: Preoperative calculation of the CSA of the hamstring tendons with MRI and US can help to reliably estimate 4ST-GT grafts. In terms of correlation of the CSA with graft diameter, US was comparable to 2x MRI, but 4x MRI showed a much greater accuracy. Threshold values of the CSA of the ST and GT of 25 mm(2), 17 mm(2), and 14 mm(2) with the 2x MRI, 4x MRI, and US methods, respectively, are needed to reliably predict a 4ST-GT graft with a minimum diameter of 8 mm.

Filiaciones:
Erquicia, JI:
 Univ Autonoma Barcelona, Inst Univ Dexeus, ICATME, Barcelona 08041, Spain

Gelber, PE:
 Univ Autonoma Barcelona, Inst Univ Dexeus, ICATME, Barcelona 08041, Spain

Doreste, JL:
 Univ Autonoma Barcelona, Inst Univ Dexeus, ICATME, Barcelona 08041, Spain

Pelfort, X:
 Univ Autonoma Barcelona, Inst Univ Dexeus, ICATME, Barcelona 08041, Spain

Abat, F:
 Univ Autonoma Barcelona, Inst Univ Dexeus, ICATME, Barcelona 08041, Spain

Monllau, JC:
 Univ Autonoma Barcelona, Inst Univ Dexeus, ICATME, Barcelona 08041, Spain
ISSN: 03635465





AMERICAN JOURNAL OF SPORTS MEDICINE
Editorial
SAGE PUBLICATIONS INC, 2455 TELLER RD, THOUSAND OAKS, CA 91320 USA, Estados Unidos America
Tipo de documento: Article
Volumen: 41 Número: 8
Páginas: 1857-1863
WOS Id: 000325708000020
ID de PubMed: 23460334

MÉTRICAS